Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
2.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38533944

RESUMEN

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Diabetes Mellitus , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros , Diálisis Renal , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
5.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38069986

RESUMEN

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Cateterismo Cardíaco , Estudios de Seguimiento , Estudios Prospectivos , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
7.
Eur Heart J Case Rep ; 7(9): ytad444, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37719005

RESUMEN

Background: The evaluation of a three-dimensional structure with a two-dimensional imaging technique makes intracoronary diagnostic techniques essential, especially in the setting of acute myocardial infarction (AMI) when no apparent coronary lesions are detected. Expert consensus recommend their use in certain scenarios such as angiographically ambiguous disease and identification of the culprit lesion. Although both intravascular ultrasound and optical coherence tomography (OCT) allow the characterization of the atherosclerotic plaque and assess the immediate and long-term results of stent implantation, they have their own benefits and limitations that make them ideal for different types of coronary lesions. Case summary: We present the case of a lateral ST-elevation myocardial infarction with no evident coronary lesions in angiography, in which OCT not only allowed us to confirm a diagonal branch occlusion, but it also became crucial to locate the occlusion point and to guide the procedure, allowing complete revascularization of the culprit lesion that otherwise could have been missed. Discussion: To know the actual limitations of conventional coronary angiography to adequately assess coronary disease, intracoronary diagnostic techniques are key to evaluate the underlying mechanisms of the event, especially in the setting of AMI when no clear culprit lesion has been identified. They can be of great value to locate and revascularize acute occlusions that could go unnoticed on the angiogram, guiding the revascularization and stent implantation and, therefore, preventing myocardial injury that could become irreversible when coronary disease is not treated promptly.

8.
Eur Heart J Case Rep ; 7(9): ytad428, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37705942

RESUMEN

Background: New percutaneous techniques for the management of acute pulmonary embolism (PE) are emerging, but there is lack of data regarding the approach of mobile thrombus in the right chambers, with the added risk of potential thrombus dislodgement that may prevent from mechanical circulatory support devices to be implanted in unstable patients. Case summary: We present the case of a 65-year-old male with cardiogenic shock of unknown aetiology, severe biventricular dysfunction, and large mobile thrombus in the right atrium. Mechanical circulatory support devices could not be implanted, and current thromboaspiration systems were either too small or not available at that time. However, the patient's condition deteriorated rapidly with thrombus in transit, hence, a novel approach was required: using a deflectable 14 Fr sheath, directional thrombectomy was performed, achieving complete extraction of the thrombi and allowing for circulatory support with extracorporeal membrane oxygenation (ECMO) to be implanted with outstanding results and progressive weaning of all intensive care measures. Discussion: Despite the growing interest in the development of percutaneous strategies for acute PE, there is no evidence-based guidelines regarding the treatment of mobile right heart thrombus. Even though some cases of percutaneous right heart thrombectomy have been reported, it is still a challenging scenario, given the potential risk of thrombus dislodgement and atrial perforation. We describe a novel technique of percutaneous directional thrombectomy in a patient with cardiogenic shock of unknown aetiology and large mobile thrombi in the right atrium as a bridge to ECMO proving to be a feasible alternative to treat thrombus in transit.

11.
Rev Esp Cardiol (Engl Ed) ; 76(11): 872-880, 2023 Nov.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36898524

RESUMEN

INTRODUCTION AND OBJECTIVES: No comparisons have been published yet regarding the newest iteration of balloon- and self-expandable transcatheter heart valves for the treatment of bicuspid aortic valve (BAV) stenosis. METHODS: Multicenter registry of consecutive patients with severe BAV stenosis treated with balloon-expandable transcatheter heart valves (Myval and SAPIEN 3 Ultra, S3U) or self-expanding Evolut PRO+(EP+). TriMatch analysis was carried out to minimize the impact of baseline differences. The primary endpoint of the study was 30-day device success, and the secondary endpoints were the composite and individual components of early safety at 30 days. RESULTS: A total of 360 patients (age 76.6±7.6 years, 71.9% males) were included: 122 Myval (33.9%), 129 S3U (35.8%), and 109 EP+(30.3%). The mean STS score was 3.6±1.9%. There were no cases of coronary artery occlusion, annulus rupture, aortic dissection, or procedural death. The primary endpoint of device success at 30 days was significantly higher in the Myval group (Myval: 100%; S3U: 87.5%; and EP+: 81.3%), mainly due to higher residual aortic gradients with S3U and greater≥moderate aortic regurgitation (AR) with EP+. No significant differences were found in the unadjusted rate of pacemaker implantation. CONCLUSIONS: In patients with BAV stenosis deemed unsuitable for surgery, Myval, S3U and EP+showed similar safety but balloon-expandable Myval had better gradients than S3U, and both balloon-expandable devices had lower residual AR than EP+, suggesting that, taking into consideration the patient-specific risks, any of these devices can be selected with optimal outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Diseño de Prótesis
15.
J Clin Med ; 11(17)2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36079140

RESUMEN

Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. Results: A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Conclusions: Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...